The Taumata Arowai Drinking Water Quality Assurance Rules provide a regulatory framework for centralised water treatment solutions, ensuring consistent and high-quality drinking water across New Zealand. These rules protect public health by setting stringent standards for water quality, treatment processes, and monitoring. The rules apply to all water supplies, ensuring providers meet rigorous standards to deliver safe drinking water.
The Acceptable Solutions offer guidelines for decentralised end-point (point-of-entry) treatment systems, catering to individual properties and smaller communities. The Acceptable Solutions provide a structed water treatment solution, ensuring all water suppliers can meet safety standards without the complexity of centralised systems. Each Acceptable Solution has distinct water quality sampling requirements tailored to their specific water source and treatment approaches, emphasizing the need for regular monitoring and compliance.
Understanding the requirements helps water supply operators ensure compliance and maintain safe drinking water, whether through centralised or decentralised systems.
Most New Zealanders don't know what's in their drinking water. Drinking contaminated water can make you and your community very unwell, with risks including giardia and other harmful pathogens. Starting in July 2025, new government legislation will require anyone responsible for a water supply to prove that their water is safe to drink.
My Water Sampling Box makes this easy with three simple steps: Test, Send, and Know.
Rules:
VSC.1
Details:
A sample of water collected from the distribution system of the supply must be analysed for E. coli and total coliforms every 6 months. There must be a period of at least 5 months between sample collection dates.
Sample collection point:
Specified locations within the distribution network
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
Bacterial | E.coli, Total Coliforms | 6-monthly | VSC 6-monthly Microbiological Monitoring | VMDN6M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
S1.1
Details:
Surface and groundwater sources must be monitored for the determinands and at the frequency set out in Table 8.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies, and at the raw water storage tank outlet for roof water supplies.
Table 8 | S1 Source water monitoring determinands for surface water and groundwater | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Every 3 months | S1 Surface and Groundwater 3-monthly Microbiological Monitoring | S1SG3M | |
Chemical | Arsenic, Boron, E.coli, Iron, Manganese, Nitrate, Total Coliforms | Every 3 years | S1 Surface and Groundwater 3-yearly Monitoring | S1SG3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
S1.2
Details:
Roof water sources must be monitored for the determinands and at the frequency set out in Table 9.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies, and at the raw water storage tank outlet for roof water supplies
Table 9 | S1 Source water monitoring determinands for roof water | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Every 3 months | S1 Roof Water 3-monthly Microbiological Monitoring | S1RM3M | |
Without chimney or open fire | Chemical | Cadmium, Copper, E.coli, Lead, Total Coliforms, Zinc | Every 3 years | S1 Roof Water 3-yearly Monitoring - Without chimney or open fire | S1RN3Y |
With chimney or open fire | Chemical | Benzo(a)pyrene, Cadmium, Copper, E.coli, Lead, Total Coliforms, Zinc | Every 3 years | S1 Roof Water + Benzo(a)pryrene 3 yearly Monitoring - With chimney or open fire | S1RY3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
T1.8
Details:
Water leaving the treatment plant must be monitored for the determinands and at the frequencies set out in Table 10.
Sample collection point:
Post treatment, from a point as close as practicable after the final treatment process.
Table 10 | T1 Treatment plant monitoring determinands. | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial and Phyiso | E.coli, Total Coliforms, Turbidity | Every 3 months | T1 3-monthly Microbiological and Turbidity Monitoring | T1MT3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
D1.1
Details:
Water in the distribution system must be monitored for the determinands and at the frequencies set out in Table 11 and any other determinands identified in the supply’s Drinking Water Safety Plan (including its Source Water Risk Management Plan.
Sample collection point:
Specified locations within the distribution network
Table 11 | D1 Distribution system monitoring determinands. | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Every 3 months | D1 3-monthly Microbiological Monitoring | D1MM3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
S2.1
Details:
Surface water and groundwater sources must be monitored for the determinands and at the frequency set out in Table 12.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies, and at the raw water storage tank outlet for roof water supplies.
Table 12 | S2 Source water monitoring determinands for surface water and groundwater. | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Monthly | S2 Surface and Groundwater Monthly Microbiological Monitoring | S2SG1M | |
Physico-chemical | E.coli, pH, Total Coliforms, Turbidity | 6-monthly | S2 Surface and Groundwater 6-monthly Monitoring | S2SG6M | |
Physico-chemical | E.coli, Iron, Manganese, Nitrate, pH, Total Coliforms, Turbidity | Annually | S2 Surface and Groundwater Annual Monitoring | S2SG1Y | |
Physico-chemical | Arsenic, Boron, E.coli, Iron, Manganese, Nitrate, pH, Total Coliforms, Turbidity | Every 3-years | S2 Surface and Groundwater 3-yearly Monitoring | S2SG3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
S2.2
Details:
Roof water sources must be monitored for the determinands and at the frequency set out in Table 13.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies, and at the raw water storage tank outlet for roof water supplies.
Table 13 | S2 Source water monitoring determinands for roof water. | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Monthly | S2 Roof Water Monthly Microbiological Monitoring | S2RM1M | |
Without chimney or open fire | Chemical | Cadmium, copper, zinc, lead (collected in winter – June, July, or August). | Every 3 years | S2 Roof Water 3-yearly Monitoring - Without chimney or open fire | S2RN3Y |
With chimney or open fire | Chemical | Cadmium, copper, zinc, lead, benzo [a] pyrene (collected in winter – June, July, or August). | Every 3 years | S2 Roof Water 3-yearly Monitoring - With chimney or open fire | S2RY3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
T2.1
Details:
Water leaving the treatment plant must be monitored for the determinands and at the frequencies set out in Table 14.
Sample collection point:
Post treatment, from a point as close as practicable after the final treatment process.
Table 14 | T2 Treated Water Monitoring Requirements | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Physico | pH, Turbidity | 2 per week | T2 Twice Weekly pH and Turbidity Monitoring | T2PH2W | |
Bacterial | E.coli, Total Coliforms | Monthly | T2 Monthly Microbiological Monitoring | T2MM1M | |
Physico | UVT | Every 3 months | T2 3-monthly Monitoring | T2PT3M | |
Physico-chemical | UVT, Chlorate | Every 3 months | T2 3-monthly Monitoring - Chlorinated water supplies | T2PC3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
D2.1
Details:
Water in the distribution system must be monitored for the determinands and at the frequencies set out in Table 15.
Sample collection point:
Specified locations within the distribution network.
D2.4 -- Samples for FAC, E. coli and total coliforms must be taken at regular sampling points that are representative of the geographical coverage of the distribution system, including some storage reservoirs/tanks and the end points of the system.
D2.6 -- Samples for metals must be collected from a sampling point near the end point of the system. Sampling taps must be flushed before samples are collected.
Table 15 | D2 Distribution System Monitoring Determinands | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Monthly | D2 Monthly Microbiological Monitoring | D2MM1M | |
Chemical | Antimony, Cadmium, Chromium, Copper, E.coli, Lead, Mercury, Nickel, Total Coliforms, Zinc | Annually | D2 Annual Monitoring | D2AM1Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
2.2(a)(SB-Pre)
Details:
The drinking water supplier must test the source water for a range of parameters to ensure the safety of the water but also to determine the suitability for cartridge filtration and UV disinfection.
Samples must represent a range of different environmental conditions such as heavy rainfall and dry periods to ensure that treatment is suitable when water quality is most likely to be at its worst.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
2.2(a)(SB-Pre) | Bacterial, chemical, physico | Arsenic, Boron, E.coli, Hardness, Iron, Manganese, Nitrate, pH, Silica, Total Coliforms, Turbidity, UVT@254nm | Pre-requisite sample - Before this Acceptable Solution can be adopted. | AS Spring and Bore Pre-requisite Analysis | SSBPAO |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
SB3
Details:
Water samples must be collected downstream of any pre-treatment system(s) but before end-point (point of entry) treatment and monitored for the following determinants:
Sample collection point:
Collected downstream of any pre-treatment system(s) but before end-point treatment.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(SB3-a) | Bacterial, chemical, physico | E.coli, Nitrate, pH, Total Coliforms, Turbidity, UVT@254nm | Every 3 months | AS Spring and Bore 3-monthly Pre-treatment Monitoring | SSBT3M |
4(a)(SB3-a&b) | Bacterial, chemical, physico | Arsenic, Boron, Hardness, Iron, Manganese, Nitrate, pH, Silica, Turbidity, UVT@254nm, Total Coliforms, E.coli | Annually | AS Spring and Bore Annual Pre-treatment Monitoring | SSBT1Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
SB5
Details:
Water samples must be collected from the treated water leaving at least one end-point (point of use) treatment system once every 3 months for:
Sample collection point:
Post treatment, water leaving an end point-treatment system. The drinking water supplier is responsible for determining the sampling schedule and locations to be sampled from (e.g., rotating the properties to be sampled from). Samples must be geographically representative of the supply.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(SB5) | Bacterial, physico | Total Coliforms, E.coli, Turbidity | Every 3 months | AS Spring and Bore 3-monthly Post-treatment Microbiological Monitoring | SSPM3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
2.2(a)(MR-Pre)
Details:
The drinking water supplier must test the source water for a range of parameters to ensure the safety of the water but also to determine the suitability for cartridge filtration and UV disinfection.
Samples must represent a range of different environmental conditions such as heavy rainfall and dry periods to ensure that treatment is suitable when water quality is most likely to be at its worst.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
2.2(a)(MR-Pre) | Bacterial, chemical, physico | Arsenic, Boron, E.coli, Hardness, Iron, Manganese, Nitrate, pH, Silica, Total Coliforms, Turbidity, UVT@254nm | Pre-requisite sample - Before this Acceptable Solution can be adopted. | AS Mixed-use Rural Pre-requisite Analysis | SMRPAO |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
MR3
Details:
Water samples must be collected downstream of any pre-treatment system(s) but before end-point (point of entry) treatment and monitored for the following determinants:
Sample collection point:
Collected downstream of any pre-treatment system(s) but before end-point treatment.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(MR3-a) | Bacterial, chemical, physico | E.coli, Nitrate, pH, Total Coliforms, Turbidity, UVT@254nm | Every 3 months | AS Mixed-use Rural 3-monthly Pre-treatment Monitoring | SMBT3M |
4(a)(MR3-a&b) | Bacterial, chemical, physico | Arsenic, Boron, Hardness, Iron, Manganese, Nitrate, pH, Silica, Turbidity, UVT@254nm, Total Coliforms, E.coli | Annually | AS Mixed-use Rural Annual Pre-treatment Monitoring | SMBT1Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
SB5
Details:
Water samples must be collected from the treated water leaving at least one end-point (point of use) treatment system once every 3 months for:
Sample collection point:
Post treatment, water leaving an end point-treatment system. The drinking water supplier is responsible for determining the sampling schedule and locations to be sampled from (e.g., rotating the properties to be sampled from). Samples must be geographically representative of the supply.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(MR5) | Bacterial, physico | Total Coliforms, E.coli, Turbidity | Every 3 months | AS Mixed-use Rural 3-monthly Post-treatment Microbiological Monitoring | SSPM3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
RF3
Details:
Collected rainwater must be monitored for the following determinands at least once between June and August when this drinking water acceptable solution is first adopted and then every three years between June and August:
Sample collection point:
Collected rainwater, from tank, prior to treatment
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(RF3) - Without chimney or open fire | Chemical | Cadmium, Copper, Lead, Zinc | July, 3-yearly | AS Roof 3-yearly Monitoring - Without chimney or open fire | SRNC3Y |
4(a)(RF3) - With chimney or open fire | Chemical | Cadmium, Copper, Lead, Zinc, Benzo(a)pyrene | July, 3-yearly | AS Roof 3-yearly Monitoring - With chimney or open fire | SRYC3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
RF5
Details:
A sample for E.coli and Total Coliforms must be taken from treated water leaving each end-point (point of entry) treatment system at least once every three months.
Sample collection point:
Collected from treated water leaving each end-point treatment system.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(RF5) | Bacterial, physico | Total Coliforms, E.coli, Turbidity | Every 3 months | AS Roof 3-monthly Post-treatment Microbiological Monitoring | SRPM3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
VSC.1
Details:
A sample of water collected from the distribution system of the supply must be analysed for E. coli and total coliforms every 6 months. There must be a period of at least 5 months between sample collection dates.
Sample collection point:
Specified locations within the distribution network
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
Bacterial | E.coli, Total Coliforms | 6-monthly | VSC 6-monthly Microbiological Monitoring | VMDN6M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
S1.1
Details:
Surface and groundwater sources must be monitored for the determinands and at the frequency set out in Table 8.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies, and at the raw water storage tank outlet for roof water supplies.
Table 8 | S1 Source water monitoring determinands for surface water and groundwater | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Every 3 months | S1 Surface and Groundwater 3-monthly Microbiological Monitoring | S1SG3M | |
Chemical | Arsenic, Boron, E.coli, Iron, Manganese, Nitrate, Total Coliforms | Every 3 years | S1 Surface and Groundwater 3-yearly Monitoring | S1SG3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
S1.2
Details:
Roof water sources must be monitored for the determinands and at the frequency set out in Table 9.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies, and at the raw water storage tank outlet for roof water supplies
Table 9 | S1 Source water monitoring determinands for roof water | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Every 3 months | S1 Roof Water 3-monthly Microbiological Monitoring | S1RM3M | |
Without chimney or open fire | Chemical | Cadmium, Copper, E.coli, Lead, Total Coliforms, Zinc | Every 3 years | S1 Roof Water 3-yearly Monitoring - Without chimney or open fire | S1RN3Y |
With chimney or open fire | Chemical | Benzo(a)pyrene, Cadmium, Copper, E.coli, Lead, Total Coliforms, Zinc | Every 3 years | S1 Roof Water + Benzo(a)pryrene 3 yearly Monitoring - With chimney or open fire | S1RY3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
T1.8
Details:
Water leaving the treatment plant must be monitored for the determinands and at the frequencies set out in Table 10.
Sample collection point:
Post treatment, from a point as close as practicable after the final treatment process.
Table 10 | T1 Treatment plant monitoring determinands. | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial and Phyiso | E.coli, Total Coliforms, Turbidity | Every 3 months | T1 3-monthly Microbiological and Turbidity Monitoring | T1MT3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
D1.1
Details:
Water in the distribution system must be monitored for the determinands and at the frequencies set out in Table 11 and any other determinands identified in the supply’s Drinking Water Safety Plan (including its Source Water Risk Management Plan.
Sample collection point:
Specified locations within the distribution network
Table 11 | D1 Distribution system monitoring determinands. | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Every 3 months | D1 3-monthly Microbiological Monitoring | D1MM3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
S2.1
Details:
Surface water and groundwater sources must be monitored for the determinands and at the frequency set out in Table 12.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies, and at the raw water storage tank outlet for roof water supplies.
Table 12 | S2 Source water monitoring determinands for surface water and groundwater. | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Monthly | S2 Surface and Groundwater Monthly Microbiological Monitoring | S2SG1M | |
Physico-chemical | E.coli, pH, Total Coliforms, Turbidity | 6-monthly | S2 Surface and Groundwater 6-monthly Monitoring | S2SG6M | |
Physico-chemical | E.coli, Iron, Manganese, Nitrate, pH, Total Coliforms, Turbidity | Annually | S2 Surface and Groundwater Annual Monitoring | S2SG1Y | |
Physico-chemical | Arsenic, Boron, E.coli, Iron, Manganese, Nitrate, pH, Total Coliforms, Turbidity | Every 3-years | S2 Surface and Groundwater 3-yearly Monitoring | S2SG3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
S2.2
Details:
Roof water sources must be monitored for the determinands and at the frequency set out in Table 13.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies, and at the raw water storage tank outlet for roof water supplies.
Table 13 | S2 Source water monitoring determinands for roof water. | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Monthly | S2 Roof Water Monthly Microbiological Monitoring | S2RM1M | |
Without chimney or open fire | Chemical | Cadmium, copper, zinc, lead (collected in winter – June, July, or August). | Every 3 years | S2 Roof Water 3-yearly Monitoring - Without chimney or open fire | S2RN3Y |
With chimney or open fire | Chemical | Cadmium, copper, zinc, lead, benzo [a] pyrene (collected in winter – June, July, or August). | Every 3 years | S2 Roof Water 3-yearly Monitoring - With chimney or open fire | S2RY3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
T2.1
Details:
Water leaving the treatment plant must be monitored for the determinands and at the frequencies set out in Table 14.
Sample collection point:
Post treatment, from a point as close as practicable after the final treatment process.
Table 14 | T2 Treated Water Monitoring Requirements | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Physico | pH, Turbidity | 2 per week | T2 Twice Weekly pH and Turbidity Monitoring | T2PH2W | |
Bacterial | E.coli, Total Coliforms | Monthly | T2 Monthly Microbiological Monitoring | T2MM1M | |
Physico | UVT | Every 3 months | T2 3-monthly Monitoring | T2PT3M | |
Physico-chemical | UVT, Chlorate | Every 3 months | T2 3-monthly Monitoring - Chlorinated water supplies | T2PC3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
D2.1
Details:
Water in the distribution system must be monitored for the determinands and at the frequencies set out in Table 15.
Sample collection point:
Specified locations within the distribution network.
D2.4 -- Samples for FAC, E. coli and total coliforms must be taken at regular sampling points that are representative of the geographical coverage of the distribution system, including some storage reservoirs/tanks and the end points of the system.
D2.6 -- Samples for metals must be collected from a sampling point near the end point of the system. Sampling taps must be flushed before samples are collected.
Table 15 | D2 Distribution System Monitoring Determinands | ||||
---|---|---|---|---|---|
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
Bacterial | E.coli, Total Coliforms | Monthly | D2 Monthly Microbiological Monitoring | D2MM1M | |
Chemical | Antimony, Cadmium, Chromium, Copper, E.coli, Lead, Mercury, Nickel, Total Coliforms, Zinc | Annually | D2 Annual Monitoring | D2AM1Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
2.2(a)(SB-Pre)
Details:
The drinking water supplier must test the source water for a range of parameters to ensure the safety of the water but also to determine the suitability for cartridge filtration and UV disinfection.
Samples must represent a range of different environmental conditions such as heavy rainfall and dry periods to ensure that treatment is suitable when water quality is most likely to be at its worst.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
2.2(a)(SB-Pre) | Bacterial, chemical, physico | Arsenic, Boron, E.coli, Hardness, Iron, Manganese, Nitrate, pH, Silica, Total Coliforms, Turbidity, UVT@254nm | Pre-requisite sample - Before this Acceptable Solution can be adopted. | AS Spring and Bore Pre-requisite Analysis | SSBPAO |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
SB3
Details:
Water samples must be collected downstream of any pre-treatment system(s) but before end-point (point of entry) treatment and monitored for the following determinants:
Sample collection point:
Collected downstream of any pre-treatment system(s) but before end-point treatment.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(SB3-a) | Bacterial, chemical, physico | E.coli, Nitrate, pH, Total Coliforms, Turbidity, UVT@254nm | Every 3 months | AS Spring and Bore 3-monthly Pre-treatment Monitoring | SSBT3M |
4(a)(SB3-a&b) | Bacterial, chemical, physico | Arsenic, Boron, Hardness, Iron, Manganese, Nitrate, pH, Silica, Turbidity, UVT@254nm, Total Coliforms, E.coli | Annually | AS Spring and Bore Annual Pre-treatment Monitoring | SSBT1Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
SB5
Details:
Water samples must be collected from the treated water leaving at least one end-point (point of use) treatment system once every 3 months for:
Sample collection point:
Post treatment, water leaving an end point-treatment system. The drinking water supplier is responsible for determining the sampling schedule and locations to be sampled from (e.g., rotating the properties to be sampled from). Samples must be geographically representative of the supply.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(SB5) | Bacterial, physico | Total Coliforms, E.coli, Turbidity | Every 3 months | AS Spring and Bore 3-monthly Post-treatment Microbiological Monitoring | SSPM3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
2.2(a)(MR-Pre)
Details:
The drinking water supplier must test the source water for a range of parameters to ensure the safety of the water but also to determine the suitability for cartridge filtration and UV disinfection.
Samples must represent a range of different environmental conditions such as heavy rainfall and dry periods to ensure that treatment is suitable when water quality is most likely to be at its worst.
Sample collection point:
Samples must be collected at the source abstraction point or treatment plant (prior to treatment) for surface or groundwater supplies.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
2.2(a)(MR-Pre) | Bacterial, chemical, physico | Arsenic, Boron, E.coli, Hardness, Iron, Manganese, Nitrate, pH, Silica, Total Coliforms, Turbidity, UVT@254nm | Pre-requisite sample - Before this Acceptable Solution can be adopted. | AS Mixed-use Rural Pre-requisite Analysis | SMRPAO |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
MR3
Details:
Water samples must be collected downstream of any pre-treatment system(s) but before end-point (point of entry) treatment and monitored for the following determinants:
Sample collection point:
Collected downstream of any pre-treatment system(s) but before end-point treatment.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(MR3-a) | Bacterial, chemical, physico | E.coli, Nitrate, pH, Total Coliforms, Turbidity, UVT@254nm | Every 3 months | AS Mixed-use Rural 3-monthly Pre-treatment Monitoring | SMBT3M |
4(a)(MR3-a&b) | Bacterial, chemical, physico | Arsenic, Boron, Hardness, Iron, Manganese, Nitrate, pH, Silica, Turbidity, UVT@254nm, Total Coliforms, E.coli | Annually | AS Mixed-use Rural Annual Pre-treatment Monitoring | SMBT1Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
SB5
Details:
Water samples must be collected from the treated water leaving at least one end-point (point of use) treatment system once every 3 months for:
Sample collection point:
Post treatment, water leaving an end point-treatment system. The drinking water supplier is responsible for determining the sampling schedule and locations to be sampled from (e.g., rotating the properties to be sampled from). Samples must be geographically representative of the supply.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(MR5) | Bacterial, physico | Total Coliforms, E.coli, Turbidity | Every 3 months | AS Mixed-use Rural 3-monthly Post-treatment Microbiological Monitoring | SSPM3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
RF3
Details:
Collected rainwater must be monitored for the following determinands at least once between June and August when this drinking water acceptable solution is first adopted and then every three years between June and August:
Sample collection point:
Collected rainwater, from tank, prior to treatment
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(RF3) - Without chimney or open fire | Chemical | Cadmium, Copper, Lead, Zinc | July, 3-yearly | AS Roof 3-yearly Monitoring - Without chimney or open fire | SRNC3Y |
4(a)(RF3) - With chimney or open fire | Chemical | Cadmium, Copper, Lead, Zinc, Benzo(a)pyrene | July, 3-yearly | AS Roof 3-yearly Monitoring - With chimney or open fire | SRYC3Y |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here
Rules:
RF5
Details:
A sample for E.coli and Total Coliforms must be taken from treated water leaving each end-point (point of entry) treatment system at least once every three months.
Sample collection point:
Collected from treated water leaving each end-point treatment system.
Determinand group | Determinants | Sampling frequency | Product Name | SKU | |
---|---|---|---|---|---|
4(a)(RF5) | Bacterial, physico | Total Coliforms, E.coli, Turbidity | Every 3 months | AS Roof 3-monthly Post-treatment Microbiological Monitoring | SRPM3M |
The longer interval tests include all the determinants from shorter interval tests. For instance, an annual test will include the 6-monthly, 3-monthly, and monthly determinants, as applicable.
Scroll here